The viscoelastic technology used in the Patient Comfort System was initially developed in conjunction with NASA to help manage the high g-force tissue loads experienced by astronauts during space flight.
The basis of this technology is an expanded urethane cellular matrix with viscoelastic properties; in essence it is a solid with the behavior of a fluid. This material is highly effective in forming to body contours and distributing body weight.
These mattresses redistribute the load (patient body weight) from areas of high concentration to areas of low concentration by two processes:
1. Immersion, which decreases the pressure by increasing the contact area.
2. Envelopment, which is the micro-configuration of the support surfaces over the body, thereby decreasing peak pressure.
The result is a pressure equilibrium which helps to maintain normal blood flow allowing the skin and underlying tissues to be perfused properly.
Peak Pressure
Peak pressures are observed typically at the bony prominences of the head, scapulae, sacrum, trochanteric head, and heels. These pressures are experienced when the support material has lost the ability to redistribute load away from these prominences. As increased pressure compresses the tissues between the surface and the underlying bone, blood flow is shunted away from the area. This results in decreased oxygen perfusion to the underlying tissue and is experienced by the patient initially as discomfort and ultimately as pain. The standard table pads used today on MRI or other imaging tables are made of resilient foams which produce uneven pressure distribution and areas of peak pressures. The discomfort associated with peak pressure is a primary reason that patients move during MRI scans. These patients are moving to relieve the pressure forces and thereby allow blood flow and oxygenation back into the body areas that had been deprived. The Patient Comfort System automatically allows for dynamic changes in the pressure profile and thus maintains tissue blood flow and oxygenation, resulting in greater patient comfort and significantly less motion.
The Mechanism of "Bottoming Out"
It is important to know that peak pressure is a problem that results in patient discomfort and, to the furthest extreme, tissue damage. It is important to understand what causes this. Peak pressure loads are primarily the result of a phenomenon commonly referred to as bottoming out. This is a term borrowed from the support surface industry to describe what happens when a patient comes into contact with the surface on which a support mattress has been installed. The practical impact is that there is no longer any pressure redistribution and peak pressures result.
Traditional foam pads allow the patient to bottom out when they become so compressed and hard, or simply worn out, that the redistribution of weight is no longer possible. As weight becomes increasingly concentrated (peak pressure), there is essentially no way for the body to relieve venous congestion. The pressure spikes associated with bottoming out commonly occur in the occipital area, sacrum, heal, trochanters, and scapula. When external forces are greater than the internal blood pressure of the capillaries, blood flow is severely restricted resulting in tissue ischemia, pain, discomfort and erythema (one of the earliest signs of a pressure ulcer).
Research
Extensive studies of patients with spinal injuries, amputation, multiple sclerosis and end stage renal disease have shown that Patient Comfort Systems mattresses and positioners decrease the average interface pressure and significantly decrease the peak loading pressures. This has been shown to reduce pressure ulcers, back pain and sciatica. This redistribution of pressure over a larger area is what makes these pads so comfortable.
Patient Comfort Systems pads incorporate ultra-strong fabric along with sewn and welded seams to protect core material from bodily fluids. This construction also prevents cracking and tearing at the pad corners, where exposure is greatest. Both the viscoelastic pad cores and cover fabrics are manufactured using a permanent antimicrobial agent to inhibit the growth of harmful bacteria. The vapor and moisture-impervious cover will not allow fluids to pass through it and can be cleaned with any standard approved hospital disinfectant. It also stretches, thereby decreasing shear and maceration. This material increases patient comfort when compared to standard plastics covers.
Patient surveys have clearly demonstrated that when given a choice, patients will overwhelmingly choose the Patient Comfort System over the standard table pads.
What is most relevant to medical imaging centers are studies which show that Patient Comfort Systems mattresses manufactured with viscoelastic materials, significantly decrease motion during MRI scans. This means fewer callbacks for imaging centers and hospitals and higher quality studies.
Covering Materials
The material covering the pads is made from advanced breathable but waterproof polymer which allows easy maintenance and cleaning. It is also vapor-permeable and can stretch, thereby decreasing shear and maceration. This material increases patient comfort when compared to the standard plastic covers that cannot breathe.
For a complete list of referral customers please contact a customer service representative at 866-529-3526.